PRINCIPLES OF OPERATION
The unit is capable of pre-locating distance to fault in three distinct modes.
– TDR
In the TDR (Time domain Reflectometer) mode the instrument transmits a pulse which is reflected off the far end of the cable. Any impedance mismatches (i.e. Joints, open or short circuits) along the cable are also reflected. The waveforms are easy to analyze.
– Impulse Current
In the Impulse Current Mode a high voltage discharge generated by a surge generator is applied to a faulty cable until the fault breaks down. Thus, the surge energy is then reflected back to its source. Upon arriving at the source it is reflected back into the cable. This continues until the
energy is depleted. The PCA101 will capture and store the current waveform flowing in the cable and display it for analysis.
– ARC-Echo
In the ARC-Echo mode the instrument is connected to the faulty cable via the AE101 Coupling unit. This unit provides the suitable isolation and filtering required to superimpose a TDR waveform on top of the high voltage surge generated by the surge generator. When the high voltage energy arrives at the fault it temporarily breaks it down causing a short term short circuit. The waveforms are simple and easy to analyze and look exactly like TDR waveforms.
Adret
PCA101
PRE-LOCATION SCOPE
The Adret PCA101 was developed to assist power cable fault location technicians in pre-locating and predetermining distances to faults existing in power cables. It gives a direct reading in meters to the fault distance. Fault distances can also be determined from the far end of the cable by simply moving two cursors to any two points on the display screen. It is capable of locating low resistance (that is any fault lower than about 120 ohms or infinity ohms) or high resistance faults with the help of any standard impulse generator and the Adret AE101 high voltage coupling unit.
SPECIFICATION
Weight : 3Kg
Dimensions : 300 x 300 x 130 mm
Controls : Watertight front panel with integrated multi-function tactile membrane switches
Power Source : Rechargeable NiMH battery pack (charger with standard accessories). Battery life approximately 4 hours for continuous use
Display : 240 x 320 Pixel Transmissive LCD with multilevel grey scaling (permanently backlit)
Enclosure : Scratch resistant PVC enclosure with lifetime guarantee.
ACCESSORIES
Standard Padded canvas carry case
All necessary cables
Switch mode battery charger and power supply
Operator manual